* SUBR CHECK REV D-2 2 PAGE 1
0001 * SUBR CHECK REV D-2 25-11-70
0002 * SUBR CHECK REV D 26-10-70
0003 * RECEIVES BIT PATTERN OF CONTROL REGIS
0004 * TER AND COMPARES IT WITH PRESET PAT-
0005 * TERN. IF SAME RETURNS IF NOT ANALYSES
0006 * FAULT AND SELECTS A STOPPING PROGRAME
0007 * WIND DOWN
0008 * INTERRUPT - WHEN 15 VOLTS ARE OFF
0009 * OFF - IN EMERGENCY
0010 REL
0011 SUBR CHECK
0012 SUBR CNTR DUMMY CALL,ACCESS MAIN PR
0013 00000 0 000000 CHEC DAC **
0014 00001 0 02 00134 LDA =-87
SET TIMER FOR 10 MSEC.
0015 00002 0 04 00107 STA TIME
0016 00003 54 1500 STRT INA '1500
0017 00004 0 01 00003 JMP *-1
0018 00005 0 04 00106 STA SAVC
0019 00006 0 03 00133 ANA ='75717
IS PATTERN OK?
0020 00007 0 05 00132 ERA ='51717
0021 00010 101040 SNZ
0022 00011 -0 01 00000 JMP*
CHEC YES - EXIT
0023 00012 0 12 00107 IRS TIME TIMER
0024 00013 0 01 00003 JMP STRT NOT 10 MSEC YET.
0025 00014 0 02 00106 LDA SAVC NO
0026 00015 0 03 00131 ANA ='10000
MAIN PRESSURE ON?
0027 00016 101040 SNZ
0028 00017 0 01 00071 JMP OFF NO
0029 00020 0 02 00106 LDA SAVC
0030 00021 0 03 00130 ANA ='4000
0031 00022 100040 SZE INTERRUPT ON?
0032 00023 0 01 00076 JMP INT
0033 00024 0 02 00106 LDA SAVC NO
0034 00025 0 03 00127 ANA ='17
0035 00026 0 05 00127 ERA ='17
ARE FLIP-FLOPS OK?
0036 00027 101040 SNZ
0037 00030 0 01 00035 JMP ANLS YES
0038 00031 0 02 00127 LDA ='17
NO
0039 00032 0 10 00000 CALL HOLD RESET THEM
0040 00033 0 01 00003 JMP STRT THEY ARE RESET
0041 00034 0 01 00003 JMP STRT ERROR RETURN
0042 00035 0 02 00106 ANLS LDA SAVC
0043 00036 0 03 00126 ANA ='1700
0044 00037 0404 72 LGR 6
0045 00040 0 06 00111 ADD JMP! SELECT JUMP
0046 00041 0 04 00042 STA *+1
0047 00042 0 00 00000 JMP PZE
0048 00043 101000 NOP ....
0049 00044 101000 NOP ...1
0050 00045 101000 NOP ..1.
0051 00046 0 01 00071 JMP OFF ..11
0052 00047 101000 NOP .1..
0053 00050 0 01 00076 JMP INT .1.l
0054 00051 101000 NOP .11.
0055 00052 0 01 00101 JMP WIND .111
0056 00053 101000 NOP 1...
0057 00054 0 01 00076 JMP INT 1..1